Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Arch Cardiovasc Dis ; 114(5): 407-414, 2021 May.
Artículo en Inglés | MEDLINE | ID: covidwho-1240128

RESUMEN

BACKGROUND: The coronavirus disease 2019 (COVID-19) has been a fast-growing worldwide pandemic. AIMS: We aimed to investigate the incidence of cardiac arrhythmias among a large French cohort of implantable cardioverter defibrillator recipients over the first 5 months of 2020. METHODS: Five thousand nine hundred and fifty-four implantable cardioverter defibrillator recipients were followed by remote monitoring during the COVID-19 period (from 01 January to 31 May 2020). Data were obtained from automated remote follow-up of implantable cardioverter defibrillators utilizing the Implicity® platform. For all patients, the type of arrhythmia (atrial fibrillation, ventricular tachycardia or ventricular fibrillation), the number of ventricular arrhythmia episodes and the type of implantable cardioverter defibrillator-delivered therapy were recorded. RESULTS: A total of 472 (7.9%) patients presented 4917 ventricular arrhythmia events. An increase in ventricular arrhythmia incidence was observed after the first COVID-19 case in France, and especially during weeks #10 and #11, at the time of major governmental measures, with an increase in the incidence of antitachycardia pacing delivered therapy. During the 11 weeks before the lockdown order, the curve of the percentage of live-stream television coverage of COVID-19 information matched the ventricular arrhythmia incidence. During the lockdown, the incidence of ventricular arrhythmia decreased significantly compared with baseline (0.05±0.7 vs. 0.09±1.2 episodes per patient per week, respectively; P<0.001). Importantly, no correlation was observed between ventricular arrhythmia incidence and the curve of COVID-19 incidence. No changes were observed regarding atrial fibrillation/atrial tachycardia episodes over time. CONCLUSIONS: An increase in ventricular arrhythmia incidence was observed in the 2 weeks before the lockdown order, at the time of major governmental measures. Ventricular arrhythmia incidence decreased dramatically during the lockdown.


Asunto(s)
Arritmias Cardíacas/epidemiología , COVID-19/epidemiología , Desfibriladores Implantables , Monitoreo Ambulatorio/métodos , Tecnología de Sensores Remotos/métodos , SARS-CoV-2 , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Femenino , Estudios de Seguimiento , Francia/epidemiología , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio/instrumentación , Monitoreo Ambulatorio/estadística & datos numéricos , Estudios Prospectivos , Cuarentena , Tecnología de Sensores Remotos/instrumentación , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA